MLS MLSH041 Installationshandbuch Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 30
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
LBI-38425A ALIGNMENT AND TROUBLESHOOTING PROCEDURES
16
5.1.7 Audio Output Level Adjustment Procedure
STEP
METERING
POINT
TUNING
CONTROL
METER
READING PROCEDURE
1 J701-1 RV601 See
Procedure
Set the signal generator to the
receiver frequency with ±3 kHz
deviation and 1 kHz modulation.
Set the RF signal level to 1000
microvolts. Move P551 from
J551-1, 2 to J551-2, 3 on the
Transmitter/Receiver Board.
Connect RF signal generator to J1.
Terminate J701-1, 6 with a 4 ohm,
6-watt resistor, connect the audio
level meter and the distortion
analyzer input across the resistor.
Set the volume to the maximum
point. Press DOWN button two
times. Adjust RV601 for 4-watt
output (4 Vrms, using the
distortion analyzer as voltmeter).
Return P551 to J551-1, 2.
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 29 30

Kommentare zu diesen Handbüchern

Keine Kommentare